Smart sportswear design that can detect vital parameters
Main Article Content
Abstract
The subject of wearable electronics is expanding quickly, and it has just lately begun to provide profitable commercial items to the consumer electronics market. It is anticipated that the use of biopotential signals in wearable systems as either biofeedback or command commands will revolutionize.There are numerous technologies, such as brain-computer interfaces, point-of-care health monitoring systems, rehabilitation tools. Since electrodes are seen to be a crucial component of such items, they have been researched for about ten years, which has led to the development of textile electrodes.In this paper , wearable devices for sport is studied with detecting vital parameters. There are a few sensors such as ECG and IMU based acceleration. Smart textile products are used for testing and taking data purpose
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
References
Tao, X. Wearable Electronics and Photonics; Elsevier: Amsterdam, The Netherlands, 2005 . DOI: https://doi.org/10.1533/9781845690441
Wearable Electronics and Technology Market by Applications. Available online: http://www. marketsandmarkets.com/Market-Reports/wearable-electronics-market-983.html (accessed on 27 April 2019).
Hu, E.; Kaynak, A.; Li, Y. Development of a cooling fabric from conducting polymer coated fibres: Proof of concept. Synth. Met. 2005, 150, 139–143. DOI: https://doi.org/10.1016/j.synthmet.2005.01.018
Khan, A.; Hussain, M.; Nur, O.; Willander, M. Fabrication of zinc oxide nanoneedles on conductive textile for harvesting piezoelectric potential. Chem. Phys. Lett. 2014, 612, 62–67. DOI: https://doi.org/10.1016/j.cplett.2014.08.009
Mehta, D.D.; Nazir, N.T.; Trohman, R.G.; Volgman, A.S. Single-lead portable ECG devices: Perceptions and clinical accuracy compared to conventional cardiac monitoring. J. Electrocardiol. 2015, 48, 710–716. DOI: https://doi.org/10.1016/j.jelectrocard.2015.04.017
Sun, F.; Yi, C.; Li, W.; Li, Y. A wearable H-shirt for exercise ECG monitoring and individual lactate threshold computing. Comput. Ind. 2017, 92–93, 1–11. DOI: https://doi.org/10.1016/j.compind.2017.06.004
Guzik, P.; Marek, M. ECG by mobile technologies. J. Electrocardiol. 2016, 49, 894–901. DOI: https://doi.org/10.1016/j.jelectrocard.2016.07.030
Jung, J.; Lee, J.; Lee, J.; Kim, Y.T. A smartphone-based U-Healthcare system for real-time monitoring of acute myocardial infarction. Int. J. Commun. Syst. 2015, 28, 2311–2325. DOI: https://doi.org/10.1002/dac.3033
Baig, M. M.; Gholamhosseini, H.; Connolly, M. J. A comprehensive survey of wearable and wireless ECG monitoring systems for older adults. Med. Biol. Eng. Comput. 2013, 51, 485–495. Electronics 2021, 10, 608 11 of 11 DOI: https://doi.org/10.1007/s11517-012-1021-6
Spano, E.; Pascoli, S.D.; Iannaccone, G. Low-power wearable ECG monitoring system for multiple-patient remote monitoring. IEEE Sensors J. 2016, 16, 5452–5462. DOI: https://doi.org/10.1109/JSEN.2016.2564995
Ozkan, H.; Ozhan, O.; Karadana, Y.; Gulcu, M.; Macit, S.; Husain, F. A Portable Wearable Tele-ECG Monitoring System. IEEE Trans. Instrum. Meas. 2020, 69, 173–182. DOI: https://doi.org/10.1109/TIM.2019.2895484
Dias, D.; Paulo Silva Cunha, J. Wearable health devices—vital sign monitoring, systems and technologies. Sensors 2018, 18, 2414. DOI: https://doi.org/10.3390/s18082414
Patel, S.; Park, H.; Bonato, P.; Chan, L.; Rodgers, M. A review of wearable sensors and systems with application in rehabilitation.J. Neuroeng. Rehabil. 2012, 9, 1-17. DOI: https://doi.org/10.1186/1743-0003-9-21
Van Loon, K.; van Zaane, B.; Bosch, E.J.; Kalkman, C.J.; Peelen, L.M. Non-invasive continuous respiratory monitoring on general hospital wards: A systematic review. PLoS ONE 2015, 10, e0144626. DOI: https://doi.org/10.1371/journal.pone.0144626
Nicolò, A.; Massaroni, C.; Schena, E.; Sacchetti, M. The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise. Sensors 2020, 20, 6396 DOI: https://doi.org/10.3390/s20216396
Di Tocco, J., Raiano, L., Sabbadini, R., Massaroni, C., Formica, D., Schena, E. (2021). A wearable system with embedded conductive textiles and an imu for unobtrusive cardio-respiratory monitoring. Sensors, 21(9), 3018. DOI: https://doi.org/10.3390/s21093018
Beck, S., Laufer, B., Krueger-Ziolek, S., Moeller, K. (2020). Measurement of respiratory rate with inertial measurement units. Current Directions in Biomedical Engineering, 6(3), 237-240. DOI: https://doi.org/10.1515/cdbme-2020-3060
Guo, L., Peterson, J., Qureshi, W., Kalantar Mehrjerdi, A., Skrifvars, M., Berglin, L. (2011). Knitted wearable stretch sensor for breathing monitoring application. In Ambience'11, Borås, Sweden, 2011.
AD8232, D. S. (2013). Single-Lead, Heart Rate Monitor Front End. Analog Device.
InvenSense. (2013). MPU-6050 Datasheet.
Manullang, M. C. T., Simanjuntak, J., Ramdani, A. L. (2019). Implementation of AD8232 ECG Signal Classification Using Peak Detection Method For Determining RST Point. Indonesian Journal of Artificial Intelligence and Data Mining, 2(2), 61-66. DOI: https://doi.org/10.24014/ijaidm.v2i2.7593
Yang, X., Wang, Y., Du, J., Huang, R., & Liu, G. (2020, November). Study on Vibration Monitoring of Railway Seamless Line. In 2020 IEEE International Conference on Information Technology, Big Data and Artificial Intelligence (ICIBA) (Vol. 1, pp. 539-544). IEEE. DOI: https://doi.org/10.1109/ICIBA50161.2020.9277383