Comparison of sterile inhalation water in oxygen humidifier bottles with tap water and investigation of antibacterial effects and endotoxin limits
Main Article Content
Abstract
In hospitals, medical air feeders and oxygen are used to create dry gas. Patients who need oxygen may experience upper respiratory tract problems due to inhalation of dry oxygen. Therefore, the airway must be humidified while the patient is receiving oxygen. This humidification process is carried out using sterilized water. Oxygen flowmeter is an instrument used in hospitals to adjust the level of oxygen gases. Sterile inhalation waters connected to these flowmeters are used in inpatient wards, intensive care units, operating rooms and all areas where oxygen needs to be administered to the patient. In this study, parameters that will affect water quality such as endotoxin limits, antimicrobial effects and heavy metals contained in untreated, non-sterile tap water and disposable sterile inhalation waters were compared with international norms such as ISO 22519 Standard and European Pharmacopoeia. As a result of the analyzes, it has been proven that the waters contained in the sterile inhalation system produced by Estaş comply with international norms.
In addition, it is foreseen that if sterile water cannot be used in hospitals, antibacterial, antiviral, antimicrobial negative effects will occur or if the same water is used more than once, cross-contamination will occur and different indications will occur. The use of sterile inhalation waters in accordance with the instructions for use reduces the risk of possible infection and ensures that the patient's saturation value reaches the desired level and provides ease of breathing. This solution aims to improve patient care conditions by reducing the risk of infection.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
References
Karim, S. S. A., Churchyard, G. J., Karim, Q. A., & Lawn, S. D. (2009). HIV infection and tuberculosis in South Africa: an urgent need to escalate the public health response. the Lancet, 374(9693), 921-933. DOI: https://doi.org/10.1016/S0140-6736(09)60916-8
WHO (2021) “The-Life-Saving-Power-of-Medical-Oxygen.” https:// www.who.int/news-room/feature-stories/detail/the-life-saving power-of-medical-oxygen. Accessed 24 Aug 2021.
Edwards, P., Therriault, P. A., & Katz, I. (2018). Onsite production of medical air: is purity a problem?. Multidisciplinary Respiratory Medicine, 13, 1-3. DOI: https://doi.org/10.1186/s40248-018-0125-8
Kallstrom, T. (2002). AARC Clinical Practice Guideline: oxygen therapy for adults in the acute care facility–2002 revision & update. Respir care, 47, 717.
Ahlgren, W. E. (1977). Pseudomonas aeruginosa infection potential of oxygen humidifier devices. Respiratory Care, 22, 383-385.
Rhame, F. S., Streifel, A., McComb, C., & Boyle, M. (1986). Bubbling humidifiers produce microaerosols which can carry bacteria. Infection Control & Hospital Epidemiology, 7(8), 403-407. DOI: https://doi.org/10.1017/S0195941700064638
Moiraghi, A., Pastoris, M. C., Barral, C., Carle, F., Sciacovelli, A., Passarino, G., & Marforio, P. (1987). Nosocomial legionellosis associated with use of oxygen bubble humidifiers and underwater chest drains. Journal of Hospital Infection, 10(1), 47-50. DOI: https://doi.org/10.1016/0195-6701(87)90031-4
Koss, J. A., Conine, T. A., Eitzen, H. E., & LoSasso, A. M. (1979). Bacterial contamination potential of sterile, prefilled humidifiers and nebulizer reservoirs. Heart & Lung: the Journal of Critical Care, 8(6), 1117-1121.
Seigel, D., & Romo, B. (1990). Extended use of prefilled humidifier reservoirs and the likelihood of contamination. Respiratory care, 35(8), 806-806.
Cahill, C. K., & Heath, J. (1990). Sterile water used for humidification in low-flow oxygen therapy: is it necessary?. American journal of infection control, 18(1), 13-17. DOI: https://doi.org/10.1016/0196-6553(90)90205-7
Golar, S. D., Sutherland, L. L., & Ford, G. T. (1993). Multipatient use of prefilled disposable oxygen humidifiers for up to 30 days: patient safety and cost analysis. Respiratory care, 38(4), 343-347.
Malik, V. S., Ravindra, K., & Singh, M. (2021). COVID-19 and increasing demand for medical oxygen: can impurity be a problem?. Environmental Science and Pollution Research, 28, 66519-66521. DOI: https://doi.org/10.1007/s11356-021-16385-x
Spellberg, B., Edwards Jr, J., & Ibrahim, A. (2005). Novel perspectives on mucormycosis: pathophysiology, presentation, and management. Clinical microbiology reviews, 18(3), 556-569. DOI: https://doi.org/10.1128/CMR.18.3.556-569.2005
Klotz, S. A., Penn, C. C., Negvesky, G. J., & Butrus, S. I. (2000). Fungal and parasitic infections of the eye. Clinical microbiology reviews, 13(4), 662-685. DOI: https://doi.org/10.1128/CMR.13.4.662-685.2000
Escobar, A., & Del Brutto, O. H. (1990). Multiple brain abscesses from isolated cerebral mucormycosis. Journal of Neurology, Neurosurgery & Psychiatry, 53(5), 431-433. DOI: https://doi.org/10.1136/jnnp.53.5.431
Naik, C. A., Mathai, S. K., Sandkovsky, U. S., Ausloos, K. A., Guileyardo, J. M., Schwartz, G., ... & Grazia, T. J. (2021). Acute myocardial infarction secondary to mucormycosis after lung transplantation. IDCases, 23, e01019. DOI: https://doi.org/10.1016/j.idcr.2020.e01019
Jackman Jr, J. D., & Simonsen, R. L. (1992). The clinical manifestations of cardiac mucormycosis. Chest, 101(6), 1733-1736. DOI: https://doi.org/10.1378/chest.101.6.1733
Shaikh, M., & Birajdar, F. (2024). Ensuring Purity and Health: A Comprehensive Study of Water Quality Testing Labs in Solapur District for Community Well-being. International Journal of Innovative Science and Research Technology, 9(1), 271-281.
Bergheim, I., & Moreno‐Navarrete, J. M. (2024). The relevance of intestinal barrier dysfunction, antimicrobial proteins and bacterial endotoxin in metabolic dysfunction‐associated steatotic liver disease. European Journal of Clinical Investigation, 54(7), e14224. DOI: https://doi.org/10.1111/eci.14224